Case Studies
Optical Spectroscopy
A customer who is completing his doctorate in Chemistry at the California Institute of Technology has identified the need to measure fast optical signals using fast photo-detectors. The signal pulse width is as short as 2ns. Signals will be acquired at a 1KHz repetition rate, with a record length of 1,000 to 10,000 data points.
GAGE'S SOLUTION
The CompuScope 82G, an 8 bit, 2GS/s A/D and Scope card for PCI Bus, is the best solution for this customer. With relatively small record sets, the customer is able to keep up with the 1KHz Pulse Repeat Frequency. The customer is familiar with LabVIEW and will therefore use Gage's LabVIEW Software Development Kit to control the card in the Windows environment.
PRODUCT RECOMMENDED
CompuScope 82G 2M
CompuScope SDK for LabVIEW for Windows
This application note is provided "as is" without any warranties of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Gage Applied Technologies further does not warrant the accuracy and completeness of the material contained herein. Gage Applied Technologies may make changes to this material, or to the products described in it, at any time without notice.