Machine Tools Characterization

THE PROBLEM

This customer is involved in characterizing machine tools. In order to do this, they need five simultaneous channels capturing 12-bit samples at 50 KSPS, with a 20 us sample width. A total of 5 seconds of data is required.

GAGE'S SOLUTION

The solution to this problem is a three-card Master/Slave CompuScope 512 system, with each card having 512 Kilosamples of on-board memory.

The CompuScope 512 is a 12-bit 5 MSPS A/D card for the ISA bus. As each CompuScope 512 has two channels, this system would provide 6 channels for the customer's application. Each channel can sample at 5 MSPS or slower, with 50 KSPS being one of the preset sampling values.

For 5 seconds of data, at a sampling rate of 50 KSPS, the customer will need to store 250 Kilosamples per channel, or 500 Kilosamples per card, as shown in the following equations:

5 seconds of data per channel x 50 KSPS = 250 Ksamples per channel
250 Ksamples per channel x 2 channels per card = 500 Ksamples per card

For this reason, each card should be equipped with 512 Kilosamples of on-board memory.

PRODUCT RECOMMENDED

Three-card Master/Slave CompuScope 512 System, 512K of memory each card

This application note is provided "as is" without any warranties of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Gage Applied Technologies further does not warrant the accuracy and completeness of the material contained herein. Gage Applied Technologies may make changes to this material, or to the products described in it, at any time without notice.